Description | Facility Code | Card Number | Parity |
37-bit Tracked Format. Wiegand Format with customer-defined facility code. | 16 bits (0 – 65,535) Offset = 1 Data = 16 | 19 bits (0 – 524,287) Offset = 17 Data = 19 | 2 bits |
PAAAAAAAAAAAAAAAABBBBBBBBBBBBBBBBBBBP
EXXXXXXXXXXXXXXXXXX••••••••••••••••••
••••••••••••••••••XXXXXXXXXXXXXXXXXXO