Knowledge base 147: IA Sigma Series reading Sector encoded mifare classic cards

Knowledge base 147: IA Sigma Series reading Sector encoded mifare classic cards

This requires an IA-PRO license, if you do not have an IA-PRO license please contact sales@controlsoft.com

The following Technical Bulletin describes how to configure Identity Access to work with the Idemia Morpho SIgma Multi Series readers to allow for reading sector encoded cards which were encoded using MorphoManager using the default keys.

This is only recommended if you have an iNet access control backbone due to the usage of the default mifare keys

IA-MFK Sector Encoded cards or Biometric

1. First ensure the Identity Access software is installed, watch the following video installation guide if needed and you can find the Identity Access Licensing Guide here

2. Next please install Morpho Tool Box which is found on the IA-STD USB Drive under Extras or you can download it from our website www.controlsoft.com.

Email support@controlsoft.com if you do not have a login

3. If you require the Biometric reader to work in ACU Mode, please configure the doors, readers and groups in Identity Access by following this video setup guide  

4. Next setup your Morpho Device Profile within the IA Server Configuration application accessed from the Start Menu > All Programs > Controlsoft > IA Server Configuration

5. Log in & edit the Default Profile by following the screenshot below -


6. Change the "Log retrieval interval (Seconds)" to a minimum of 60 or if using an i-Net ACU disable this setting altogether by unchecking "Realtime logging enabled" as the i-Net handles the logs.


7. Choose "34bit Wiegand" and select “i-Net ACU Mode”.

8. Add the Morpho Device into the IA User Interface, select the Biometric Device Profile you have edited and select “Accept Users with no fingerprints”.


9. Load the Download Server and click on " Biometric Devices " tab, click the " Refresh List " button. Ensure the reader comes online and perform a rebuild. Once the Device Status is “ Ready ” and the Tasks are 0 go to the next stage.

10. Go back to the IA User Interface and double-click the Morpho Device. Under Device Profile select “External Profile”.


11. From the IA User Interface add a new Group. Management > Groups > Click the green plus icon

12. Give the group a name and then select the "Morpho Readers" tab in the Group Properties and tick the reader you created earlier.


13. Click Accept.

14. Open Morpho Tool Box (MBTB) and connect to the Device.
15. Click on the Key Configuration icon. 

16. Scroll Down and change the settings below by clicking the entry in “Local”, changing the entry and click the Green Tick.
Local Setting           
Value
sc.verify_user_id
0
Ucc.trigger_event
3
sc.read_profile
2
Wiegand.custom_format_slot0
000000004D6F7270686F4D616E616765720000000000000000000000000000000000000022000000010000002000000000000000000000000000000000000000020000000000000001000000010000000000FEFF00000000210000000000000000000000FEFF010000000000

17. Click the “Write” Button.

18. Now reboot the reader and test.